SENSOR PM (LASER)

Para poeira externa – aplicações de monitoramento da qualidade do ar Faixa de até (0-31.000 µg/m³)

Solicite um orçamento

Sensor de material particulado (PM)
recursos incríveis

  • pm sensor of Fan <div class=

    Controle do ventilador para fluxo de ar constante

  • pm sensor of Own fault <div class=

    Detecção de falhas integrada

  • pm sensor of Design of <div class=

    Design de duto à prova de poeira

  • pm sensor of Small size and easy to install

    Tamanho pequeno e fácil de instalar

  • pm sensor of Strong <div class=

    Excelente resistência a interferências

  • pm sensor of Circuit board <div class=

    Placa de circuito resistente à umidade

  • pm sensor of Multiple communication modes

    Vários modos de comunicação

  • pm sensor of Fast <div class=

    Capacidade de detecção rápida

Prana Air PM Sensor

Sensor PM
Tecnologia Laser

Método de dispersão de luz

Prana Air PM laser sensor light scattering working mechanism

PAS-OUT-01 é um sensor laser digital baseado em luz projetado para indústrias
para medir partículas – partículas de poeira. Uma vez que vem com um laser embutido e módulo de recepção baseado em luz. Diferente de seus contemporâneos, o PAS-OUT-01 é configurado com precisão para PM10 e PM2.5 Apart. Porque funciona com base no princípio da propagação da luz em 90°.

Alcance até
(0-31.000 µg/m³)

Conectividade perfeita

  • Prana Air PM sensor
  • Sensores PM

  • pm sensor and air quality monitor
  • Monitor e Sensor PM

  • wifi connectivity
  • Conectividade WiFi para o monitor

  • aqi cloud data storage
  • Transmissão de dados do sensor para nuvem.

  • aqi monitoring platforms
  • Exibindo o Sensor
    dados no celular, laptop ou TV.

O sensor PM tem um design compacto que permite que ele se encaixe facilmente em qualquer monitor de qualidade do ar. Além disso, qualquer pessoa pode integrar ou alterar o sensor sem necessitar de conhecimentos técnicos avançados. Além disso, o acesso à rede do sensor é tranquilo, pois pode transferir diretamente os dados do sensor para a nuvem para facilitar a tecnologia para os usuários.

Sensores PM para ambientes externos e internos

Os Sensores PM possuem duas opções que atendem a necessidade específica de cada ambiente para oferecer ótimo desempenho e melhor monitoramento da qualidade do ar.

Comparação de tamanho PM

PM pollutant size comparison with human hair

Material particulado ou PM é uma mistura de pequenas partículas ou gotículas de líquido. E estes também emitem no ar de diferentes fontes. Como resultado, essas partículas podem entrar nos pulmões humanos e causar muitos danos à saúde.

  • PM1 size 1µm
  • PM1

    Menor que ou 1 µm

  • PM2 size 2.5µm
  • PM2.5

    Menor que ou 2,5 µm

  • PM10 size 10µm
  • PM10

    Menor que ou 10µm

As pequenas ameaças no ar:
Partículas

O material particulado (PM) vem em vários tamanhos, como PM2,5 (partículas menores que 2,5 mícrons) e PM10 (partículas menores que 10 mícrons), o mais comum.

  • PM1 pollutant icon
    PM1
  • PM10 pollutant icon
    PM10
  • PM2.5 pollutant icon
    PM2.5
  • PM2.5 pollutant icon
    PM2.5
  • PM1 pollutant icon
    PM1
  • PM10 pollutant icon
    PM10

Conheça cada tamanho de PM

  • PM1

    PM1 são as partículas com diâmetro de 1 micrômetro ou menor, o que também inclui nanopartículas e emissões provenientes da queima. Conseqüentemente, eles podem entrar facilmente na corrente sanguínea e causar problemas de saúde.

  • PM2.5

    PM2,5 refere-se a partículas finas com diâmetro de 2,5 micrômetros ou mais menores. Devido ao seu tamanho minúsculo, estes são suficientes para penetrar profundamente nos pulmões e resultar em graves problemas de saúde.

  • PM10

    As partículas no ar com diâmetro de 10 micrômetros ou outras menores que PM10. Inclui poeira, pólen e mofo e é grande o suficiente para ficar preso principalmente no nariz ou na garganta e resultar em alergias.

  • Particle Count

    Por último, representam o número total de partículas presentes no ar, sem considerar os seus tamanhos individuais. Em vez disso, concentra-se na carga geral de partículas, incluindo partículas de vários tamanhos.

Fontes:

  • Vehicle Exhaust as source of PM pollutant
    Escape do veículo
  • Factory Emission as source of PM pollutant
    Emissão de fábrica
  • Construction sites as source of PM pollutant
    Canteiros de obras
  • Wildfires as source of PM pollutant
    Incêndios florestais
  • Dusty roads as source of PM pollutant
    Estradas empoeiradas

Nível de precisão de dados
Gráfico de comparação com BAM

data accuracy of Prana Air PM2.5 sensor comparing with BAM data

Em um estudo comparativo abrangente que avalia a precisão dos dados do sensor PM2.5 da Prana Air em relação a um sistema de monitoramento de atenuação beta (BAM) de última geração.

Furthermore, the results demonstrated a high correlation between the two devices.

Feliz em atender nossos clientes

  • Symbiosis Pune logo
  • taj logo
  • TATA Steel Jamshedpur logo
  • UOC logo
  • WRI logo
  • Adani Group logo
  • BARC Bhabha Atomic Research Centre logo
  • BCG Boston Consulting Group logo
  • BIRLA Ultratech logo
  • BITS pilani logo
  • BITS pilani logo
  • CII logo
  • CSIR NEERI logo
  • Emaar logo
  • FOOD works logo
  • Google Bangalore logo
  • IGCAR logo
  • IIT Banaras logo
  • iit hyderabad logo
  • iit kanpur logo
  • iit roorkee logo
  • InterGlobe Aviation Indigo logo
  • Larsen Toubro logo
  • Leighton logo
  • LODHA logo
  • LODHA logo
  • marriott logo
  • Microsoft logo
  • OLA logo
  • renault nissan logo
  • Schneider Electric logo
  • Siemens logo
  • Symbiosis Pune logo
  • taj logo
  • TATA Steel Jamshedpur logo
  • UOC logo
  • WRI logo
  • Adani Group logo
  • BARC Bhabha Atomic Research Centre logo
  • BCG Boston Consulting Group logo
  • BIRLA Ultratech logo
  • BITS pilani logo
  • BITS pilani logo
  • CII logo
  • CSIR NEERI logo
  • Emaar logo
  • FOOD works logo
  • Google Bangalore logo
  • IGCAR logo
  • IIT Banaras logo
  • iit hyderabad logo
  • iit kanpur logo
  • iit roorkee logo
  • InterGlobe Aviation Indigo logo
  • Larsen Toubro logo
  • Leighton logo
  • LODHA logo
  • LODHA logo
  • marriott logo
  • Microsoft logo
  • OLA logo
  • renault nissan logo
  • Schneider Electric logo
  • Siemens logo

Sensor de qualidade do ar PM
aplicações

Canteiros de obras cobertos pelo sensor PM da Prana Air

O Sensor PM tem sido usado em vários locais de construção para monitorar altos níveis de PM produzidos em diversas atividades nesses locais. Como resultado, ajuda a garantir o monitoramento em tempo real da qualidade do ar e permite intervenções oportunas quando necessário .

  • 500+

  • Sites cobertos
  • Sites cobertos

    DPCC Guidelines

PM ao ar livre
Estudo de caso

Estudo de caso do sensor laser PM – I

Avaliação comparativa de novos sensores de material particulado de baixo custo

Study Brief : Portanto, o artigo envolve nosso dispositivo Prana Air junto com outros sensores de baixo custo para medições de PM2,5 e PM10. Para obter os resultados, eles os compararam com o Aeroqual Series-500 padrão. Desde então, seu desafio com os dispositivos tradicionais era o alto custo, o peso e as frequentes necessidades de manutenção, o que limitava o uso nas cidades.

By Dr. Sachin Chaudhari,
Instituto Internacional de Tecnologia da Informação Hyderabad, Índia

comparison of PM sensor data between Aeroqual and Prana Air before and after calibration

Note : Os monitores são atualizados a cada 30 segundos, além disso, nossos sensores PM têm uma resolução de ±1,0 microgramas por metro cúbico e nossos sensores de NO2 possuem uma resolução de ±1,0 ppb.

Estudo de caso do sensor laser PM – II

Protocolo baseado em desempenho para seleção de sensor acessível e fácil de transportar para medição da qualidade do ar

Resumo do estudo : Em suas pesquisas, eles usaram nosso dispositivo na avaliação de Sensores de Proteção Ambiental (EPS). Então, eles compararam os dados de calibração de fábrica com monitores de referência. Porque o desafio deles era o custo razoável com precisão, sensibilidade e gerenciamento de dados. No resultado, o Prana Air provou ser uma escolha confiável e acessível.

By Dr. Sunil Gulia,
Instituto Nacional de Pesquisa em Engenharia Ambiental, Nova Delhi, Índia

Impactos na Saúde – Por que é importante medir o material particulado?

"Asthma

Asma e gatilhos

High risk of lung cancer as health impacts by particulate matters

Alto risco de câncer de pulmão

Respiratory infections as health impact by particulate matters

Infecções respiratórias

Lung diseases as health impact by particulate matters

Doenças pulmonares

Heart-related issues as health impact by particulate matters

Problemas relacionados ao coração

Especificações Técnicas

  • Nome do produto:

  • Sensor PM

  • Tensão nominal:

  • 5V

  • Nível da porta de comunicação:

  • 3.3 V

  • Dimensions L x W x H :

  • 4.5 x 4.5 x 2 cm

  • Resolução de tamanho de partícula:

  • 0.3 µm

  • Temperatura de armazenamento:

  • -20~85 C°

  • Temperatura de trabalho:

  • -20~70 C°

  • Umidade de trabalho:

  • 0~99C%RH (Sem formação de umidade)

  • Corrente nominal:

  • 70mA

  • Resolução de dados de concentração de massa:

  • 1 μg/m3

  • Dimensões do sensor externo

  • Prana Air outdoor PM sensor dimensions
  • Dimensões do sensor interno

  • Prana Air indoor PM sensor dimensions

Entre em contato

Por favor, ajude-nos a saber quais requisitos você tem.
Assim, nossa equipe entrará em contato com você em breve.

Informações de contato

Procurando por qualquer sensor de material particulado (PM)?

  • Phone Number:
    (+91) 73918-73918
  • Email Address:
    [email protected]
  • Office Location:
    706, 7th Floor, Sec 10,
    Rohini, Delhi 85, India

    Você também pode gostar